VW Sharan repair. Diesel engines: 1,9 l of TDI.+ 1. Introduction + 2. VR6 engine + 3. Two-liter engine (ADY) + 4. System of greasing of the engine - 5. Cooling system + 5.1. Cooling liquid + 5.2. Radiator and fan - 5.3. Pump of water cooling of the 2,0-liter engine 5.3.1. Removal and installation of the water pump + 5.4. Pump of water cooling of the VR6 engine 5.5. Thermostat of the 2,0-liter engine 5.6. VR6 engine thermostat 5.7. Poliklinova belt 5.8. The circulating pump of cooling liquid + 6. System of injection of fuel of the VR6 engine + 7. Simos system of injection of fuel of the 2,0-liter engine + 8. Ignition system + 9. Coupling + 10. Mechanical 5-step transmission + 11. Shaft of a drive of wheels + 12. Hydraulic booster of a steering + 13. Forward suspension bracket + 14. Back suspension bracket + 15. Brake system + 16. Electric equipment + 17. Diesel engine + 18. System of greasing of the diesel engine + 19. System of cooling of the diesel engine + 20. Power supply system of the diesel engine and turbokompressor + maintenance Card + Specifications and characteristics + Elektroskhema |
Repair Sharan/Sharan Volkswagen>> Cooling system>> Pump of water cooling of the 2,0-liter engine>> Removal and installation of the water pump Removal of the pump of water cooling carry out in the following order:
- merge cooling liquid from cooling system (see item 5.1.1);
- remove gear or maple a belt;
- remove a protective casing of a driving belt;
- unscrew bolts of fastening and remove a pulley 11
(fig. 188)
of the pump. To fix a pulley in motionless situation, put on it maple a belt and clamp them a pulley. If the gear belt is established, also fix a pulley in motionless situation;
- weaken clips of hoses in places of their accession to the pump and remove hoses;
- unscrew bolts of fastening of the water pump 20
(fig. 189)
and remove it from the engine;
- remove an O-shaped sealing ring 2 water pumps and check its condition.
Installation of the water pump carry out to sequences of return to removal, carrying out the following recommendations:
- bolts of fastening of the pump and a pulley tighten the moment of 20 N · m;
- a tension of a maple belt regulate the special tension adaptation.
|
|