VW Sharan repair

. Diesel engines: 1,9 l of TDI.
+ 1. Introduction
+ 2. VR6 engine
+ 3. Two-liter engine (ADY)
+ 4. System of greasing of the engine
+ 5. Cooling system
+ 6. System of injection of fuel of the VR6 engine
+ 7. Simos system of injection of fuel of the 2,0-liter engine
+ 8. Ignition system
+ 9. Coupling
+ 10. Mechanical 5-step transmission
+ 11. Shaft of a drive of wheels
+ 12. Hydraulic booster of a steering
+ 13. Forward suspension bracket
+ 14. Back suspension bracket
+ 15. Brake system
- 16. Electric equipment
   + 16.1. Storage battery
   - 16.2. Generator
      16.2.1. Precautionary measures at work in power supply system
      16.2.2. Generator check
      16.2.3. Removal and generator installation
      16.2.4. Generator repair
   + 16.3. Starter
   + 16.4. Screen wipers
   + 16.5. Headlights
   16.6. Back lamps
   16.7. Replacement of lamps of forward indexes of turn
+ 17. Diesel engine
+ 18. System of greasing of the diesel engine
+ 19. System of cooling of the diesel engine
+ 20. Power supply system of the diesel engine and turbokompressor
+ maintenance Card
+ Specifications and characteristics
+ Elektroskhema








Repair Sharan/Sharan Volkswagen>> Electric equipment>> Generator>> Generator check
External manifestations of malfunctions of system of power supply following:
- there are no signs of a charging of AB;
AB is discharged in use, but signs of violation of operation of the generator are not present;
AB is recharged;
- the generator at work publishes strong noise;
- the control lamp of a discharge of AB does not light up at ignition inclusion.
If there are no signs of a charging of AB, the reasons can be the following:
- a safety lock peregoraniye in a chain of excitement of the generator;
- easing or damages of a driving poliklinovy belt of the generator;
- break or short circuit in wires;
- malfunctions of a regulator of tension;
- malfunction of the voltmeter or chain of a control lamp of the category.
If AB is discharged in use, but signs of violation of operation of the generator are not present, the reasons can be the following:
- the wrong actions at starter inclusion;
- energy overexpenditure;
- weakening of contact connections;
- the insufficient size of tension developed by the generator (because of a faulty regulator of tension or a weak tension of a driving belt);
If AB is recharged, the reasons can be the following:
- the tension regulator is faulty;
- short circuit of a conclusion of a winding of excitement of the generator on "weight".
If the generator at work publishes strong noise, the reason of it can be:
- break of one of stator windings;
- malfunction of the vypryamitelny block;
- weakening of a nut of fastening of a pulley;
- pollution of contact rings and brushes;
- lack of greasing in bearings.
It is independently possible to check only a tension of a driving belt of the generator and a condition of coal brushes of the generator. All other verifying works should be carried out on HUNDRED.